Willele Aerosol Fire Extinguisher
Willele QRR0.01G/S
Aerosol Fire Extinguisher
Compact, heat-triggered protection for micro-spaces.
Engineered for electrical cabinets and engines.
Activates at 170°C. Discharges in ≤6s. No piping needed.

Engineered for Critical Micro-Spaces
Traditional fire suppression is too bulky for electrical cabinets. We built the QRR0.01G/S to protect where others can’t.
Ultra-Compact Design
Designed specifically for tight spaces like switchgear and battery packs (0.06m³). No piping required—it installs directly inside the hazard source.
10-Year Maintenance-Free
A true “set and forget” solution. Non-pressurized storage means no annual inspections, no pressure gauges to check, and zero maintenance costs for a decade.
Instant Thermal Activation
Detects fire heat automatically at 170°C ±6°C. The solid compound transforms into suppression aerosol in under 6 seconds, stopping fire before it spreads.
Complete Protection for Critical Assets
The QRR0.01G/S is engineered to protect high-value equipment in confined spaces where traditional sprinklers or gas systems cannot fit.
Electrical Cabinets
Prevent electrical fires at the source. Ideal for small enclosures containing high-voltage components.
- Switchgear
- Server Racks
- Distribution Panels
- Control Boxes
Vehicles & Transport
Rugged design withstands vibration. Protects engine bays and compartments on the move.
- Car Engines
- Bus Compartments
- Heavy Machinery
- Marine Vessels
Energy Storage
Suppress lithium-ion battery thermal runaway early in localized modules.
- Li-ion Batteries
- Power Banks
- ESS Containers
- Solar Inverters
Industrial Equipment
Protect expensive automated machinery and control units from internal electrical faults.
- CNC Machines
- Robotics
- Control Panels
- Manufacturing Lines
Specifications: Aerosol Fire Extinguisher QRR0.01G/S
| Product Model | QRR0.01G/S |
| Agent Dose | 10 grams (0.01 kg) |
| Protected Volume | Up to 0.06 m³ |
| Activation Temperature | 170°C ± 6°C |
| Discharge Time | ≤ 6 seconds |
| Service Life | 10 Years (Maintenance Free) |
| Operating Temperature | -50°C to +90°C |
| Net Weight | 170g ± 10g |
| Fire Classes | A, B, C, E, F |
Mechanism & Installation
Dual-Action Suppression Technology
Advanced aerosol science works on two fronts simultaneously.
1. Chemical Inhibition
Generates ultra-fine potassium particles (1-5 microns) that bind with fire radicals (H, OH), effectively breaking the combustion chain reaction instantly without depleting oxygen.
2. Physical Cooling
The discharge creates a strong endothermic reaction, absorbing heat from the flame core while blocking thermal radiation to prevent reignition of surrounding components.
Installation Guidelines
Follow these steps for optimal protection (Reference PDF Pg.7)
Site Assessment
- Verify cabinet volume ≤ 0.06m³.
- Check ambient temp (-50°C to +90°C).
- Identify optimal mounting spot.
Mounting
- Use screws or industrial adhesive.
- Ensure thermal element is exposed.
- Do not obstruct the discharge nozzle.
Safety Check
- Verify Red Indicator is visible.
- Post warning signage if required.
- Ensure enclosure is reasonably sealed.
Quality Assurance
ISO 9001 Facility
Manufactured in certified facilities with automated quality checkpoints.
Full Traceability
Unique serial number & batch info on every unit for 10-year tracking.
Stress Tested
Verified performance in high humidity (95%) and extreme temps.