Brass Terminal Block — T001 Series
High-conductivity brass bar with insulated nylon base for neutral/earth distribution.
4–18 ways; two bore options 6×9 mm (M4) or 8×12 mm (M5).
Compact footprint, low resistance, easy inspection and maintenance.
Suits distribution boards, control panels, and OEM switchgear
Overview
The brass terminal block T001 is a tidy, low-resistance solution for consolidating neutral and earth conductors in distribution boards and control panels.
Machined from solid brass and mounted on a rigid insulated base, brass terminal block T001 keeps wiring short, labels readable, and maintenance fast in compact enclosures.
Bore options of 6×9 mm (M4) and 8×12 mm (M5) cover typical cross-sections, while way counts from 4 to 18 suit residential, commercial, and light-industrial layouts.
When panel builders need repeatable torque and stable contact quality, brass terminal block T001 provides a dependable footprint that integrates with standard accessories.
Key Features
- Solid corrosion-resistant brass conductor for low contact resistance and thermal stability.
- Insulated nylon base ensures electrical isolation and secure mounting.
- Two bore sizes: 6×9 mm (M4) and 8×12 mm (M5).
- Available in 4, 6, 8, 10, 12, 14, 16, and 18 ways.
- Works as neutral (N) link or earth (PE) bar; simple inspection and re-torque.
Specifications
| Article No. | Ways | Spec (mm) | L1 (mm) | L2 Installation (mm) | Screw | Ø (mm) | Remark |
|---|---|---|---|---|---|---|---|
| T001-0609/4 | 4 | 6×9 | 71.5 | 58.5 | M4 | 5.2 | T001-0609/4B, T001-0609/4G |
| T001-0609/6 | 6 | 6×9 | 84.5 | 71.5 | M4 | 5.2 | T001-0609/6B, T001-0609/6G |
| T001-0609/8 | 8 | 6×9 | 97.5 | 84.5 | M4 | 5.2 | T001-0609/8B, T001-0609/8G |
| T001-0609/10 | 10 | 6×9 | 110.5 | 97.5 | M4 | 5.2 | T001-0609/10B, T001-0609/10G |
| T001-0609/12 | 12 | 6×9 | 123.5 | 110.5 | M4 | 5.2 | T001-0609/12B, T001-0609/12G |
| T001-0609/14 | 14 | 6×9 | 136.5 | 123.5 | M4 | 5.2 | T001-0609/14B, T001-0609/14G |
| T001-0609/16 | 16 | 6×9 | 149.5 | 136.5 | M4 | 5.2 | T001-0609/16B, T001-0609/16G |
| T001-0609/18 | 18 | 6×9 | 162.5 | 149.5 | M4 | 5.2 | T001-0609/18B, T001-0609/18G |
| T001-0812/4 | 4 | 8×12 | 73.5 | 60.5 | M5 | 6.0 | T001-0812/4B, T001-0812/4G |
| T001-0812/6 | 6 | 8×12 | 88.5 | 75.5 | M5 | 6.0 | T001-0812/6B, T001-0812/6G |
| T001-0812/8 | 8 | 8×12 | 103.5 | 90.5 | M5 | 6.0 | T001-0812/8B, T001-0812/8G |
| T001-0812/10 | 10 | 8×12 | 118.5 | 105.5 | M5 | 6.0 | T001-0812/10B, T001-0812/10G |
| T001-0812/12 | 12 | 8×12 | 133.5 | 120.5 | M5 | 6.0 | T001-0812/12B, T001-0812/12G |
| T001-0812/14 | 14 | 8×12 | 148.5 | 135.5 | M5 | 6.0 | T001-0812/14B, T001-0812/14G |
| T001-0812/16 | 16 | 8×12 | 163.5 | 150.5 | M5 | 6.0 | T001-0812/16B, T001-0812/16G |
| T001-0812/18 | 18 | 8×12 | 178.5 | 165.5 | M5 | 6.0 | T001-0812/18B, T001-0812/18G |
Dimension

Applications
Use brass terminal block T001 in consumer units, OEM control cabinets, machine panels, and PV sub-assemblies where a compact neutral or earth consolidation point reduces clutter and speeds commissioning.
Selection Guide
Choose 6×9 mm with M4 screws for compact conductors, or 8×12 mm with M5 where current margins or cable stiffness are higher.
On boards with many branch circuits, brass terminal block T001 in 16–18 ways minimizes jumpers and shortens runs.
Installation
Mount the base on a flat surface, confirm earthing strategy, and route feeders before tightening.
When space is tight, brass terminal block T001 can sit near the incoming neutral or PE stud to simplify labeling and testing.
Maintenance
Re-torque terminal screws on scheduled intervals, inspect for oxidation, and verify base fasteners.
With these checks, brass terminal block T001 maintains consistent contact performance over years of thermal cycling.
FAQ
What conductors fit the T001 series?
Use 6×9 mm bores with M4 screws for compact cross-sections, and 8×12 mm with M5 screws for larger conductors.
Neutral or earth?
Both. The bar can be wired as a neutral link (N) or an earth bar (PE), depending on your panel design.
Any guidance on torque?
Apply manufacturer-standard torque for M4/M5 screws; re-check after initial thermal cycles as part of regular maintenance.