Insulated Cord End Terminals — E Series

  • High-quality insulated cord end terminals for precise wire ferrule termination from 0.5 mm² to 50 mm².

  • Tin-plated copper sleeves with color-coded insulating collars for easy identification.

  • Ideal for stranded wire termination in control panels, terminal blocks, and distribution systems.

Get A Quotation

Insulated Cord End Terminals — E Series

WILLELE E Series insulated cord end terminals (ferrules) cover 0.5–50 mm² (AWG 22–1).
Tin-plated copper sleeves with color-coded collars make stranded conductor termination clean, safe and reliable.

  • High-conductivity copper, tin plated for corrosion resistance.
  • Insulating collar supports strands and prevents splay during crimping.
  • Color coding per size family for quick identification.
  • Compatible with standard ferrule crimp tools.

Specifications — Full List

ModelF (mm)L (mm)W (mm)B (mm)D (mm)C (mm)AWGCross Section (mm²)Color
0.5 mm² — AWG #22
E05066.012.02.66.01.31.0#220.5Orange
E05088.014.02.66.01.31.0#220.5Orange
E051010.016.02.66.01.31.0#220.5Orange
E051212.018.02.66.01.31.0#220.5Orange
0.75 mm² — AWG #20
E75066.012.42.86.41.51.2#200.75White / Blue
E75088.014.62.86.41.51.2#200.75White / Blue
E751010.016.42.86.41.51.2#200.75White / Blue
E751212.018.42.86.41.51.2#200.75White / Blue
E751818.024.42.86.41.51.2#200.75White / Blue
1.0 mm² — AWG #18
E10066.012.43.06.41.71.4#181.0Yellow / Red
E10088.014.63.06.41.71.4#181.0Yellow / Red
E101010.016.43.06.41.71.4#181.0Yellow / Red
E101212.018.43.06.41.71.4#181.0Yellow / Red
1.5 mm² — AWG #16
E15088.014.63.56.42.01.7#161.5Red / Black
E151010.016.43.56.42.01.7#161.5Red / Black
E151212.018.43.56.42.01.7#161.5Red / Black
E151818.024.43.56.42.01.7#161.5Red / Black
2.5 mm² — AWG #14
E25088.015.24.07.02.62.3#142.5Blue / Grey
E251010.017.24.07.02.62.3#142.5Blue / Grey
E251212.019.04.07.02.62.3#142.5Blue / Grey
E251818.025.04.07.02.62.3#142.5Blue / Grey
4.0 mm² — AWG #12
E40099.016.54.47.53.22.8#124.0Grey / Orange
E401212.019.54.47.53.22.8#124.0Grey / Orange
E401818.025.54.47.53.22.8#124.0Grey / Orange
6.0 mm² — AWG #10
E601016.018.06.38.03.93.5#106.0Black / Green
E601212.020.06.38.03.93.5#106.0Black / Green
E601818.026.06.38.03.93.5#106.0Black / Green
10.0 mm² — AWG #7
E10-1212.021.57.69.54.94.5#710.0Milky White / Brown Green
E10-1818.027.57.69.54.94.5#710.0Milky White / Brown Green
16.0 mm² — AWG #5
E16-1212.022.28.810.26.25.8#516.0Green / Milky White
E16-1818.028.28.810.26.25.8#516.0Green / Milky White
25.0 mm² — AWG #4
E25-1616.029.011.213.07.97.5#425.0Brown Green / Black
E25-2222.035.011.213.07.97.5#425.0Brown Green / Black
35.0 mm² — AWG #2
E35-1616.030.012.714.08.78.3#235.0Greyish / Brown
E35-2525.039.012.714.08.78.3#235.0Greyish / Brown
50.0 mm² — AWG #1
E50-2020.036.015.316.010.910.3#150.0Olive
E50-2525.041.015.316.010.910.3#150.0Olive

insulated cord end terminals size

Get a Quote

Tell us wire size and ferrule length (F). We supply insulated cord end terminals and compatible crimp tools.